Advanced Diagnostic & Interventional Radiology Research Center | Evaluation of the effect of multiple linear gadolinium based contrast agent exposures on the signal intensity of the dentate nucleus in multiple sclerosis patients

Advanced Diagnostic & Interventional Radiology Research Center | Evaluation of the effect of multiple linear gadolinium based contrast agent exposures on the signal intensity of the dentate nucleus in multiple sclerosis patients
| Dec 11 2025
logo

Advanced Diagnostic & Interventional Radiology Research Center

COVID-19 pandemic 

During the COVID-19 pandemic, the Radiology Research Center at Tehran University of Medical Sciences continued its research activities despite the challenges posed by the increased demand for CT scans of COVID-19 patients and the necessity of adhering to strict health protocols. This center played a crucial role in improving medical imaging techniques, optimizing diagnostic protocols, and advancing technologies related to CT scan image analysis.

Faculty members, researchers, and staff remained committed to ensuring the safety and well-being of healthcare professionals and patients while actively engaging in imaging data analysis, developing artificial intelligence algorithms for faster disease detection, publishing scientific articles, and presenting their findings at international conferences. These efforts aimed to enhance diagnostic accuracy, improve treatment processes, and alleviate pressure on healthcare systems.

 

Key achievements of the Radiology Research Center during the COVID-19 pandemic include:


✔️ Development and optimization of lung imaging protocols for faster and more accurate COVID-19 diagnosis
✔️ Implementation of artificial intelligence technologies for automated CT scan analysis and reduced diagnosis time
✔️ Publication of high-impact research articles on innovative imaging methods for COVID-19 patients
✔️ Participation in national and international projects focused on COVID-19 diagnosis and patient management

The center remains dedicated to advancing research in medical imaging and continues to contribute as a leading scientific institution in improving the quality of diagnostic and therapeutic services.

 

Some of the center's significant achievements during the pandemic include:

 

  • Release Date : Jul 9 2024 - 07:36
  • : 73
  • Study time : 1 minute(s)

Evaluation of the effect of multiple linear gadolinium based contrast agent exposures on the signal intensity of the dentate nucleus in multiple sclerosis patients

 dentate nucleus in multiple sclerosis patients {faces}

Background:

 Magnetic resonance imaging (MRI) with gadolinium (GAD)-based contrast agents has been the imaging modality of choice for early detection and monitoring of multiple sclerosis (MS) patients.

Objectives:

 This study aimed to assess the effect of multiple injections of linear GAD-based contrast agents on the signal intensity of the dentate nucleus (DN) in MS patients.

Patients and Methods:

 A cohort of 122 MS patients with GAD-enhanced MRI scans and 61 healthy controls were enrolled in this study. The final standard GAD-enhanced MRI scans were acquired using 1.5T MRI systems. Non-enhanced T1-weighted MRI was performed to assess the DN hyperintensity. The signal intensity ratio (SIR) was also calculated by setting the regions of interest (ROIs) on the DN and pons and dividing the signal intensity of DN to that of pons. The patients were also divided into two subgroups, based on the total number of MRI exposures (> 4 times vs. others), and the subgroups were compared in terms of the mean SIR and hyperintensity.

Results:

 Overall, 68% (n = 83) of the patients were exposed to a contrast agent more than four times. Of these patients, 31.3% (n = 26) showed DN hyperintensity, while no hyperintensity was found in other patients or healthy controls (P < 0.02 for both). The mean SIRs were 1.10 ± 0.07 and 1.04 ± 0.02 in the patients and healthy controls, respectively (P < 0.001). Besides, the mean SIR was 1.14 ± 0.04 in patients with DN hyperintensity and 1.09 ± 0.07 in other patients (P < 0.001). Based on the results, the mean SIR was 1.12 ± 0.7 in patients with > 4 contrast injections, while it was 1.06 ± 0.04 in patients with ≤ 4 contrast injections (P < 0.001).

Conclusion:

 The SIR and visible DN hyperintensity increased by increasing the number of GAD injections, which could be due to the tissue deposition of GAD
  • Article_DOI : doi.org/10.5812/iranjradiol.114397.